Genicom 5000 Series Quick ...
Genicom 5000 Series Quick Reference Guide, drukarki
[ Pobierz całość w formacie PDF ]
Genicom
5000 Series
Quick Reference Guide
GEK-99014
GEK-99013
TABLE OF CONTENTS
Table of Contents.............................................................................................1
FCC Compliance Statement (USA)....................................................................3
Compliance Statement (Canada) ......................................................................3
compliance Statement (Germany).....................................................................3
compliance Statement (Europe)........................................................................4
Optional Interface Kits .....................................................................................4
Energy Star .....................................................................................................4
International Compliance.................................................................................4
Trademark Acknowledgements ......................................................................5
Operating Precautions.................................................................................. 6
Introduction ....................................................................................................7
Models.............................................................................................................8
Description of the Operator Control Panel ........................................................8
Beeper ......................................................................................................... 9
Display ........................................................................................................ 9
Pushbuttons ................................................................................................ 9
Operation of the Control Panel .......................................................................10
Basic Pushbutton Use................................................................................ 10
Power Switch ............................................................................................. 11
Loading Paper – 50 dBa (5050/5100) Cabinet Model and 55 dBa
(5050/5100/5180) Cabinet Model..................................................................11
Manual Paper Loading ............................................................................... 11
Semiautomatic Paper Loading .................................................................... 16
Horizontal Positioning of the Paper ................................................................17
The Ribbon Deck – 50 & 55 dBa (5050/5100) Cabinet Model Printers ............20
The Ribbon Cartridge – 50 & 55 dBa (5050/5100) Cabinet Model Printers......20
Ribbon Removal and Installation – 50 & 55 dBa (5050/5100) Cabinet Model
Printers .........................................................................................................21
Removing a Ribbon .................................................................................... 21
Replacing the Ribbon ................................................................................. 23
Installation and Removal of Ribbon – 55 dBa (5180) Cabinet Model................25
Optimizing Print Quality ................................................................................26
Reading the Scale....................................................................................... 27
Using the White Scale ................................................................................ 27
Using the Black Scale................................................................................. 27
5000 Series Quick Reference Guide
1
GEK-99012
Low Paper Printing.........................................................................................27
Low Paper .................................................................................................. 27
LCD Menu Maps............................................................................................28
Cleaning Procedure........................................................................................34
Fault and Error Conditions ............................................................................37
Hard Faults................................................................................................ 37
Soft Faults ................................................................................................. 38
Electrical Problems .................................................................................... 39
Mechanical Problems ................................................................................. 40
Self-test Error Messages............................................................................. 41
Additional Options Available ..........................................................................41
5000 Series Quick Reference Guide
2
GEK-99012
FCC COMPLIANCE STATEMENT (USA)
This equipment complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of
the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment to an outlet on a circuit different from that to
which the receiver is connected.
FCC Warning
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
•
Consult the dealer or an experienced radio/TV technician for help.
Note the following:
•
The use of a non-shielded interface cable with the referenced device is
prohibited.
•
The length of the parallel interface cable must be 3 meters (10 feet) or
less.
•
The length of the serial interface cable must be 15 meters (50 feet) or
less.
•
The length of the power cord must be 3 meters (10 feet) or less.
COMPLIANCE STATEMENT (CANADA)
This digital apparatus is in conformity with standard NMB-003 of
Canada.
Cet appareil numérique est conforme à la norme NMB-003 du Canada.
COMPLIANCE STATEMENT (GERMANY)
Bescheinigung des Herstellers/Importeurs
Hermit wird bescheinigt, daß der/die/das
Machinenlärminformationsverordnung 3. GSGV, 18.01.1991: Der
höchste
Schalldruckpegel beträgt 70 dB (A) oder weniger gemäß EN27779-1991.
5000 Series Quick Reference Guide
3
GEK-99012
Warning
This product meets the interference requirements of EN55022. In a
domestic environment, this product may cause radio interference in
which case, the user may be required to take adequate measures.
COMPLIANCE STATEMENT (EUROPE)
OPTIONAL INTERFACE KITS
If either Ethernet interface boards, Token ring interface board, IBM
TX/CX interface board, or any variation of the Legacy parallel board is
installed in either or both of the interface expansion slots, this
equipment may produce additional radio frequency interference in
compliance with FCC Class A emissions.
Si des panneaux d’interface d’Ethernet, panneau de token ring, panneau
d’IBM TX/CX, ou n’importe quelle variation des panneaux de parallèle de
legs est installé dans l’un ou l’autre ou tous les deux emplacements
d’interface, ce matérial peut produire l’interférence F.R. upplémentaire
conformément ICES-003 aux émissions de la classe A.
Falls Ethernet, Token ring, IBM TX/CX, Schnittstellenkarten oder eine
variation der herkoemmlicken Parallelscnittstellenkarten (interface) in
einer oder beiden steckbaren Erweiterungsschnittstellen installiert sind,
koennen moeglicherweise zusaetzliche Funkfrequenzstoerungen erzeugt
werden, unter Einhaltung der EN55022 Klasse A Stoerstrahlungswerte.
ENERGY STAR
As an ENERGY STAR ® Partner, GENICOM has determined that this
product meets the ENERGY STAR ® guidelines for energy efficiency. The
International ENERGY STAR ® Office Equipment Program is an
international program that promotes energy saving through the use of
computers and other office equipment. The program backs the
development and dissemination of products with functions that
effectively reduce energy consumption. It is an open system in which
business proprietors can participate voluntarily. The targeted products
are office equipment such as computers, displays, printers, facsimiles,
and copiers. Their standards and logos are uniform among participating
nations.
INTERNATIONAL COMPLIANCE
EN5008-1:1993
EN55022:1994
EN50082-1:1997
EN61000-4-2:1995
EN61000-4-3:1994
EN61000-4-4:1995
EN61000-4-5:1995
EN61000-4-6:1994
5000 Series Quick Reference Guide
4
GEK-99012
[ Pobierz całość w formacie PDF ]